Ethernet bonding configuration on Digi AWUSB Plus

AWUSB Hub supports two modes for network "bonding" connection.

-First mode is Active-Backup.

Active-backup policy: Only one slave in the bond is active. A different slave becomes active if, and only if, the active slave fails.
The bond's MAC address is externally visible on only one port (network adapter) to avoid confusing the switch.
Active-Backup mode does not require any additional configurations on a switch to what the AWUSB Hub ports connected.
This mode provides only a backup/failover.

-Second mode is Round-robin.

Round-robin policy: Transmit packets in sequential order from the first available slave through the last.
The round-robin bonding mode generally requires that the switch to what the AWUSB Hub ports connected have the appropriate ports grouped together.
The nomenclature for such a group differs between switches, it may be called an “etherchannel” (as in the Cisco example, above), a “trunk group” or some other similar variation.
For this mode, each switch will also have its own configuration options for the switch's transmit policy to the bond.
The transmit policy of the two peers does not need to match.
Round-robin mode does not support IEEE 802.3ad Dynamic link aggregation protocol (LACP) that Utilizes all slaves in the active aggregator according to the 802.3ad specification.
 
 
You can find a guide how to create a bonding interface below:
 
On the menu, click System. Under Configuration, click Device Configuration.
Then click Network > Ethernet bonding.
For Add Bond device, click +
For Mode, select an Active-backup from the drop down menu.
Click to expand Devices.
Add appropriate Ethernet interfaces:
For Add device, click +
Click Apply to save the configuration and apply the change.




Last updated: Jan 25, 2021